GMI X1-NIS-RLI-01-S Safety relay SIL3 24/220-Vdc/Vac Voltage Transistor-Out Detector

GMI X1-NIS-RLI-01-S Safety relay SIL3 24/220-Vdc/Vac Voltage Transistor-Out Detector

Model: X1-NIS-RLI-01-S

Supplier: GMI

Categories: Safety Relay

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

GMI X1-NIS-RLI-01-S Safety relay SIL3 24/220-Vdc/Vac Voltage Transistor-Out Detector



Description:


The Vdc/Vac Voltage Detector X1-NIS-RLI-01 module is a unit suitable for applications requiring SIL 3 level in safety related systems for high risk industries. The module is able to reflect the presence of a 24 to 220 Vac/Vdc nominal input signal to the output by closing an optically coupled open-collector transistor, which guarantees reinforced insulation to the field. The input voltage presence is also indicated by a yellow LED on the front panel. DC signals have a separated interface for a faster response time. To ease maintenance operations, field devices can be disconnected through a two-position insertion/extraction mechanism. This product requires a dedicated Termination Board.


FEATURES:


  1. SIL 3 / SC 3

  2. Installation in Zone 2 / Division 2

  3. Loop disconnection to ease maintenance operations

  4. Separate interface for DC signals for faster response time

  5. Reinforced insulation, Field to System

  6. Three port isolation, Input/Output/Supply

General

Power Dissipation0.45 W, @ 24 Vdc System Supply, 220 Vac input voltage and 10 mA output current, typical.

System Supply

Voltage24 Vdc nom (18 to 30 Vdc).
Current Consumption15 mA, @ 24 Vdc with closed output contact, typical.

System Out

TypeVoltage free SPST optocoupled open-collector transistor. 
Max voltage35 Vdc.
Max current50 mA. 
Max voltage drop1.5 V @ 50 mA.
Leakage current≤ 50 μA @ 35 Vdc.
Response time≤ 1 ms (DC input), ≤ 100 ms (AC input).

Field In (AC Source)

TypeAC Voltage signal. 
Voltage range0 to 250 Vrms.
Switching thresholdsOFF ≤ 15 Vrms, ON ≥ 20 Vrms.
Input impedance500 kΩ, typical.

Field In (DC Source)

TypeDC Voltage signal.
Voltage range0 to 250 V.
Switching thresholdsOFF ≤ 14 V, ON ≥ 17 V.
Input impedance400 kΩ, typical.

Isolation

Test VoltageField In/System Out 2.5 kV; Field In/System Supply 2.5 kV; System Out/System Supply 500 V.

Environmental conditions

Operating temperaturetemperature limits –40 to +70 °C.
Storage temperaturetemperature limits –45 to +80 °C.

Mounting

TypeOn custom Termination Board. 
Weightabout 50 g.
DimensionsWidth 10 mm, Depth 80 mm, Height 120 mm.

...