GMI D5090S-086 Safety relay SIL3 Relay Out Module for 5 A NE Loads

GMI D5090S-086 Safety relay SIL3 Relay Out Module for 5 A NE Loads

Model: D5090S-086

Supplier: GMI

Categories: Safety Relay

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

GMI D5090S-086 Safety relay SIL3 Relay Out Module for 5 A NE Loads


Description:

The D5090-086 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NC contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NO contact for service purpose. A wide compatibility towards different DCS/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.


FEATURES:

  • SIL 3 / SC 3 for NE loads with ND driver

  • Installation in Zone 2

  • Up to 5 A functional / 6 A inrush current

  • Load disconnection on both supply lines available

  • Compatible with DCS/PLC pulse testing

  • Service contact available

  • Input/Output isolation


Input

Type24 Vdc nom (21.6 to 27.6 Vdc), reverse polarity protected. Relay coils are internally protected with suppressor diodes.
Current Consumption45 mA @ 24 Vdc, typical.
Power Dissipation1.1 W @ 24 Vdc, typical.

Output

Type1 voltage free SPDT relay contact identified with outputs: Out 1 (NC contact) terminals 7-11 and Service Load Out (NO contact) terminals 9-10; 1 voltage free SPST relay contact identified with output Out 2 (NC contact) terminals 8-12. Terminals 7-11 (Out 1) and 8-12 (Out 2) are closed when relay is de-energized, open in energized relay condition. Service load output (not SIL) at terminals 9-10 is normally open when relay is de-energized, closed in energized relay condition.
Contact materialAg Alloy (Cd free), gold plated.
Contact rating5 A 250 Vac 1250 VA, 5 A 250 Vdc 140 W (resistive load).
Contact min. switching current1 mA.
Contact inrush current6 A @ 24 Vdc, 250 Vac.
DC and AC load breaking capacityrefer to Instruction Manual.
Mechanical / electrical life5 * 10⁶ / 3 * 10⁴ operation, typical.
Operate / release time50 / 40 ms typical.

Isolation

Test VoltageInput / All Outputs 2.5 kV; Out 1 / Out 2 500V.

Environmental conditions

Operating temperaturetemperature limits -40 to +70 °C.
Storage temperaturetemperature limits -45 to +80 °C.

Mounting

TypeDIN-Rail 35 mm, or on custom Term. Board.
Weightabout 125 g.
Connectionby polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.

...




For more inquiry,please contact me freely,


Contact: Jellery Xu  


+86 15071090630(Whatsapp&Wechat)


Email: jellery@hkxytech.com & jellery@whxyauto.com


Related Products