GMI D5090S-102 Safety relay SIL3 Relay Out Low-Power Module for 5 A NE Loads


Description:

The D5090-102 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. This model is specifically designed to reach high functional safety at minimum power consumption and low input voltage. Compatibility with specific DO cards with pulse testing needs to be verified.


FEATURES:

  • SIL 3 / SC 3 for NE loads with NE driver

  • Installation in Zone 2/Div. 2

  • Up to 5 A functional / 6 A inrush current

  • Load disconnection on both supply lines available

  • Low current consumption

  • Service contact available

  • Input/Output isolation


Input

Type24 Vdc nom (20 to 28.8 Vdc), reverse polarity protected. Relay coils are internally protected with suppressor diodes
Current Consumption30 mA @ 24 Vdc, typical.
Power Dissipation0.72 W @ 24 Vdc, typical.

Output

Type1 voltage free SPDT relay contact identified with outputs: Out 1 (NO contact) terminals 7-11 and Service Load Out (NC contact) terminals 9-10; 1 voltage free SPST relay contact identified with output Out 2 (NO contact) terminals 8-12. Terminals 7-11 (Out 1) and 8-12 (Out 2) are open when relay is de-energized, closed in energized relay condition. Service load output (not SIL) at terminals 9-10 is normally close when relay is de-energized, open in energized relay condition.
Contact materialAg Alloy (Cd free), gold plated.
Contact rating5 A 250 Vac 1250 VA, 5 A 250 Vdc 140 W (resistive load).
Contact min. switching current1 mA.
Contact inrush current6 A @ 24 Vdc, 250 Vac.
DC and AC load breaking capacityrefer to Instruction Manual.
Mechanical / electrical life5 * 10⁶ / 3 * 10⁴ operation, typical.
Operate / release time55 / 30 ms, typical.

Isolation

Test VoltageIn/Outs 2.5 kV; Out 1/Out 2 500 V.

Environmental conditions

Operating temperaturetemperature limits -40 to +70 °C.
Storage temperaturetemperature limits -45 to +80 °C.

Mounting

TypeDIN-Rail 35 mm, or on custom Term. Board.
Weightabout 125 g.
Connectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.

...