GMI D5095S Safety relay SIL3 Relay Out Module for 5 A NE/ND Loads

GMI D5095S Safety relay SIL3 Relay Out Module for 5 A NE/ND Loads

Model: D5095S

Supplier: GMI

Categories: Safety Relay

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

GMI D5095S Safety relay SIL3 Relay Out Module for 5 A NE/ND Loads


Description:

The D5095 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NC relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) / F&G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.


FEATURES:

  1. SIL 3 / SC 3 for NE/ND loads with ND/NE driver

  2. Installation in Zone 2

  3. Up to 5 A functional / 6 A inrush current

  4. Load disconnection on both supply lines available

  5. High process availability to avoid spurious trips

  6. Compatible with DCS/PLC pulse testing

  7. Service contact available

  8. Input/Output isolation


Input

Type24 Vdc nom (21.6 to 27.6 Vdc), reverse polarity protected. Relay coils are internally protected with suppressor diodes.
Current Consumption45 mA @ 24 Vdc, typical.
Power Dissipation1.1 W @ 24 Vdc, typical.

Output

TypeVoltage free 2+2 SPST relay contact (2 paralleled contacts in series) at terminals 7-11 and 8-12, close when relay de-energized, open in energized condition.
Contact materialAg Alloy (Cd free), gold plated.
Contact rating5 A 250 Vac 1250 VA, 5 A 250 Vdc 140 W (resistive load).
Contact min. switching current1 mA.
Contact inrush current6 A @ 24 Vdc, 250 Vac.
DC and AC load breaking capacityrefer to Instruction Manual.
Mechanical / electrical life5 * 10⁶ / 3 * 10⁴ operation, typical.
Operate / release time30 ms / 30 ms, typical.

Isolation

Test VoltageOutput/Input 2.5 kV.

Environmental conditions

Operating temperaturetemperature limits –40 to +70 °C.
Storage temperaturetemperature limits -45 to +80 °C.

Mounting

TypeDIN-Rail 35 mm, or on custom Term. Board.
Weightabout 125 g.
Connectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.

...




For more inquiry,please contact me freely,