GMI D50978D Safety relay SIL3 Relay Out Module for 5 A NE Loads

GMI D50978D Safety relay SIL3 Relay Out Module for 5 A NE Loads

Model: D50978D

Supplier: GMI

Categories: Safety Relay

After sales service. If you have any questions, click here.

PRODUCT DESCRIPTION

GMI D50978D Safety relay SIL3 Relay Out Module for 5 A NE Loads


Description:

The D5098 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available NO contacts for up to two Normally Energized (NE) loads and NC contacts for service purpose. A wide compatibility towards different DCS/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.



FEATURES:

  • SIL 3 / SC 3 for NE loads with NE driver

  • Installation in Zone 2

  • Up to 5 A functional / 6 A inrush current

  • Compatible with DCS/PLC pulse testing

  • Service contact available

  • Input/Output isolation

  • High Density, two channels per unit


Input

Type24 Vdc nom (21.6 to 27.6 Vdc), reverse polarity protected. Relay coils are internally protected with suppressor diodes.
Current Consumption25 mA/channel @ 24 Vdc, typical.
Power Dissipation0.6 W/channel, @ 24 Vdc, typical.

Output

Type1 voltage free SPDT relay contact identified with outputs: Out 1 (NO contact) terminals 7-8 and Service Load Out 1 (NC contact) terminals 7-11; 1 voltage free SPDT relay contact identified with outputs Out 2 (NO contact) terminals 9-10 and Service Load Out 2 (NC contact) terminals 9-12 (only for D5098D). Terminals 7-8 (Out 1) and 9-10 (Out 2, only for D5098D) are open when relay is de-energized, closed in energized relay condition. Service load outputs (not SIL) at terminals 7-11 and 9-12 (only for D5098D) are normally closed when relay is de-energized, open in energized relay condition.
Contact materialAg Alloy (Cd free), gold plated.
Contact rating5 A 250 Vac 1250 VA, 5 A 250 Vdc 140 W (resistive load).
Contact min. switching current1 mA.
Contact inrush current6 A @ 24 Vdc, 250 Vac.
DC and AC load breaking capacityrefer to Instruction Manual.
Contact current deratingrefer to Instruction Manual.
Mechanical / electrical life5 * 10⁶ / 3 * 10⁴ operation, typical.
Operate / release time30 ms / 20 ms, typical.

Isolation

Test VoltageOutput/Input 1.5 kV; Input/Input 500 V; Output/Output 1.5 kV.

Environmental conditions

Operating temperaturetemperature limits –40 to +70 °C.
Storage temperaturetemperature limits -45 to +80 °C.

Mounting

TypeDIN-Rail 35 mm, or on custom Term. Board.
Weightabout 150 g
Connectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.

...




For more inquiry,please contact me freely,


Contact: Jellery Xu  


+86 15071090630(Whatsapp&Wechat)


Email: jellery@hkxytech.com & jellery@whxyauto.com