Description:

The D5095 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NC relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) / F&G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.


FEATURES:

  • SIL 3 / SC 3 for NE loads with NE driver

  • Installation in Zone 2

  • Up to 5 A functional / 6 A inrush current

  • Compatible with DCS/PLC pulse testing

  • Service contact available

  • Input/Output isolation


Input

Type24 Vdc nom (21.6 to 27.6 Vdc), reverse polarity protected. Relay coils are internally protected with suppressor diodes.
Current Consumption45 mA @ 24 Vdc, typical
Power Dissipation1.1 W (D5098D), @ 24 Vdc, typical.

Output

Type1 voltage free SPDT relay contact identified with outputs: Out 1 (NO contact) terminals 7-8 and Service Load Out 1 (NC contact) terminals 7-11; 1 voltage free SPDT relay contact identified with outputs Out 2 (NO contact) terminals 9-10 and Service Load Out 2 (NC contact) terminals 9-12 (only for D5098D). Terminals 7-8 (Out 1) and 9-10 (Out 2, only for D5098D) are open when relay is de-energized, closed in energized relay condition. Service load outputs (not SIL) at terminals 7-11 and 9-12 (only for D5098D) are normally closed when relay is de-energized, open in energized relay condition.
Contact materialAg Alloy (Cd free), gold plated.
Contact rating5 A 250 Vac 1250 VA, 5 A 250 Vdc 140 W (resistive load).
Contact min. switching current1 mA.
Contact inrush current6 A @ 24 Vdc, 250 Vac.
DC and AC load breaking capacityrefer to Instruction Manual.
Contact current deratingrefer to Instruction Manual.
Mechanical / electrical life5 * 10⁶ / 3 * 10⁴ operation, typical.
Operate / release time30 ms / 20 ms, typical.

Isolation

Test VoltageOutput/Input 1.5 kV; Input/Input 500 V; Output/Output 1.5 kV.

Environmental conditions

Operating temperaturetemperature limits –40 to +70 °C.
Storage temperaturetemperature limits -45 to +80 °C.

Mounting

TypeDIN-Rail 35 mm, or on custom Term. Board.
Weightabout 110 g
Connectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 12.5 mm, Depth 123 mm, Height 120 mm.

...